Asee peer logo

A Novel Fluid Flow Demonstration/Unit Operations Experiment

Download Paper |

Conference

2003 Annual Conference

Location

Nashville, Tennessee

Publication Date

June 22, 2003

Start Date

June 22, 2003

End Date

June 25, 2003

ISSN

2153-5965

Conference Session

Innovations in the CHE Laboratory

Page Count

18

Page Numbers

8.88.1 - 8.88.18

DOI

10.18260/1-2--12445

Permanent URL

https://peer.asee.org/12445

Download Count

1735

Request a correction

Paper Authors

author page

Ronald Willey

author page

Ralph Buonopane

author page

Deniz Turan

author page

Alfred Bina

author page

Guido Lopez

Download Paper |

Abstract
NOTE: The first page of text has been automatically extracted and included below in lieu of an abstract

Session 2313

A Novel Fluid Flow Demonstration/Unit Operations Experiment

Ronald J. Willey, Guido Lopez, Deniz Turan, Ralph A. Buonopane, and Alfred J. Bina

Department of Chemical Engineering, Northeastern University, Boston, MA 02115

Abstract Demonstration of laminar and turbulent flow using water in one experimental unit has always been a challenge. One can achieve one of the two defined flow regimes by varying tube diameter; however, the versatility to move across a decade or more in Reynolds number with a single tube diameter is generally difficult. A unit operations fluid flow experiment composed of a two ¾-inch ID glass tubes, 36 inches long, has been developed that allows demonstration of flow in all flow regimes with ease. One of the tubes is empty and contains no flow elements (typical flow inside a pipe); the other tube contains a multi-element, 33-inch long, static mixer. Using a secondary dye injection system, students conduct experiments in which the various flow regimes (laminar, transition, or turbulent) may be observed in the empty tube. The effects of the static mixer blending the dye into the water stream can be observed in the other tube. Students record the flow effects in their experiments using still and motion digital photography. Pressure transducers, located at the entrances and exits of the tubes, allow quantitative measurement of pressure drop across each tube to be observed. Students can then compare their results with pressure loss predictions using information found in the literature such as a Fanning Friction Chart. The experiment has been technically successful and is very popular with our students. This paper presents the evolution of this experiment and on the results that students are able to observe and evaluate. Nomenclature D Inside diameter of pipe or tube, m F Frictional pressure losses in flow systems, m2/s2 f Fanning friction factor, dimensionless fM Moody friction factor, dimensionless L Length of tubing, m Leq Equivalent length of tubing for similar pressure drop, m P System pressure, N/m2 Re Reynolds number (defined in Equation 1), dimensionless v• velocity, m/s V Volumetric flow rate, m3/s Subscripts 1 Entrance condition 2 Exit condition ref Reference condition “Proceedings of the 2003 American Society for Engineering Education Annual Conference & Exposition Copyright © 2003, American Society for Engineering Education”

Willey, R., & Buonopane, R., & Turan, D., & Bina, A., & Lopez, G. (2003, June), A Novel Fluid Flow Demonstration/Unit Operations Experiment Paper presented at 2003 Annual Conference, Nashville, Tennessee. 10.18260/1-2--12445

ASEE holds the copyright on this document. It may be read by the public free of charge. Authors may archive their work on personal websites or in institutional repositories with the following citation: © 2003 American Society for Engineering Education. Other scholars may excerpt or quote from these materials with the same citation. When excerpting or quoting from Conference Proceedings, authors should, in addition to noting the ASEE copyright, list all the original authors and their institutions and name the host city of the conference. - Last updated April 1, 2015